Quick Details

  • Place of Origin: Beijing, China (Mainland)
  • Brand Name: GFUVE
  • Model Number: GF302D
  • Power: Electronic
  • Usage: Auto Testing Machine
  • GF302D: three phase Electric Meter Testing System
  • Accuracy class: 0.05%/0.1%
  • Range: 57.7V, 100V, 220V, 380V
  • Adjustment range: (0-120)%RG
  • Adjustment fineness: 0.01%RG, 0.1%RG, 1%RG, 10%RG as optional
  • Stability: <0.05%/120s
  • Distortion: ≤0.5% (Non-capacitive load)
  • Output load: each phase 25VA
  • Measuring accuracy: 0.05%RG
  • Active power output stability: <0.05%RG/120s

Packaging & Delivery

Packaging Details Inside a layer of aluminum alloy box, outside is packed in wooden cases
Delivery Time 15days upon receipt of firm order

Application of Three phase Kwh Meter testing equipment GF302D high precision Electric Meter Testing System with power source ,CE,ISO9001:2008,IEC approved,english version display,with two years quality warranty.

 

This test equipment is used for grid corporation of measurement and test center, management department of power supply bureau, national energy measurement of testing authorities, and also used to test each kind of single/three phase kWh meter of industries and mining enterprises as well as electric meter manufacturers. Meanwhile, the calibrator also can be used as one high standard power source.

 

Features & Functions

Able to test basic error, shunt running, start, standard error automatically and manually in single-step of single/three phase, according to relative regulation of kWh meter.

     Able to do change test caused by voltage influence, frequency influence and harmonic influence.

Output of power source is speedy and stable, AC maximum output of each phase can reach 100A in maximum.

Voltage, current and phase position of each phase can be adjusted in split-phase, improving the flexibility of power source.

Frequency of each impulse input port can reach 40Hz.

LCD in color and big screen, complete English menu, simple and convenient operation, commonly used functions and current basic load point can be controlled in one button.

Each meter position can provide one standard, dependent RS485 port, and able to do multi-function test such as communication test.

Each meter position can provide six-pulse input port, able to connect active power pulse, reactive power pulse, clock pulse, finishing the whole test process automatically, solving the problems of changing pulse line.

Impulse port of each meter position, external polarity can be set randomly, able to adapt kWh meter of impulse cascade and common-anode.

 

Technical Specification

 

AC Voltage Output & Measurement

Range: 57.7V, 100V, 220V, 380V;

Adjustment range: (0-120)%RG

Adjustment fineness: 0.01%RG, 0.1%RG, 1%RG, 10%RG as optional.

Stability: <0.05%/120s.

Distortion: ≤0.5% (Non-capacitive load);

Output load: each phase 25VA;

Measuring accuracy: 0.05%RG;

(RG means range, the same as below)

AC Current Output & Measurement

Range: 200mA, 1A, 5A, 20A, 100A;

Adjustment range: (0-120)%RG

Adjustment fineness: 0.01%RG, 0.1%RG, 1%RG, 10%RG as optional.

Stability: <0.05%/120s.

Distortion: ≤0.5% (Non-capacitive load);

Output load: 45VA;

Accuracy: 0.05%RG

Power Output & Measurement

Active power output stability: <0.05%RG/120s;

Reactive power output stability: <0.05%RG/120s;

Active power measuring accuracy: 0.05%RG;

Reactive power measuring accuracy: 0.1%RG.

Phase Output & Measurement

Output adjustment range: 0-359.99;

Output adjustment fineness:10, 1, 0.1, 0.01 as optional.

Resolution: 0.001

Measurement accuracy: 0.0005

Frequency Output

Adjustment range: 45Hz-69Hz;

Output adjustment fineness: 5Hz, 1Hz, 0.1Hz, 0.01Hz as optional.

Resolution:0.001Hz;

Accuracy:0.005Hz;

Voltage /Current/Harmonic Setting

Harmonic number:2-31times;

Harmonic content:0-40%;

Harmonic phase:0-359.99;

Harmonic setting accuracy:(10%±0.1%)RD.

RD means the settled harmonic content, harmonic can be a single output, also multiple output.

Power Energy Measurement Error

Active power energy: 0.05%RG;

Reactive power energy: 0.1%RG;

Power Pulse Output

Power pulse type: support active pulse and reactive pulse.

Active power pulse output is 5V, output is 10mA.

Power Pulse Input

Energy pulse type: support active and reactive pulse, the highest frequency power pulse input is 180K.

Dimension

500mmx600mmx175mm;

Weight: About 27KG;

Power Supply: One Phase AC 180~265V , frequency 50/60Hz;

 

 

Certifications

 

Transaction History of the Supplier

Below is the information about the supplier's transactions conducted via Alibaba.com. If you require further details regarding the transaction data, please contact the supplier directly.

Transaction Overview

Transactions

Transaction Details

This supplier has completedtransactions with buyers from .

Shipping Destination
Transaction Value
Transaction Date
Email to this supplier
China (Mainland) | Trading Company
Supplier Assessments:
The supplier supports Trade Assurance – A free service that protects your orders from payment to delivery.
Supplier's Trade Assurance Limit: US $50,000
Learn More