Current transducer price with 0-5A 0-10V

FOB Reference Price:Get Latest Price
US $0-100 / Piece | 1 Piece/Pieces (Min. Order)
Supply Ability:
1000 Piece/Pieces per Month
Port:
Beijing/Shenzhen
Report Suspicious Activity
Overview
Quick Details
Place of Origin:
Beijing, China (Mainland)
Brand Name:
GFUVE
Model Number:
FUD-3I
Usage:
Other
Theory:
Current Sensor
Output:
Digital Sensor
Accuracy:
0.2%, 0.5%
AC input range:
0-10A, 0-500V(Optional), 50/60Hz
Power supply:
AC110V,220V,DC110V--330V
DC output range:
0-5V, 0-20mA, RS485
Consumption:
≤5VA
Accutacy drift:
Annual Variation < 0.2%
Surge voltage:
5KV
Response Time:
≤350ms
Installation:
35mm DIN Sliding-way or M4 screws
Dimension:
110mmX75mmX120mm
Packaging & Delivery
Packaging Details
standard export carton
Delivery Time
7 days from receipt of payment

Specifications

The devices have been developed, manufactured and tested in accordance with Quality Assurance System ISO 9001.

FUD-3I Real RMS din rail ac current transducer

 

Product Description

 Function & Feature

Transforms the measured AC current/voltage to the DC current/voltage output according to the linear scale

Excellent temperature characteristic and good working stability

Configuration compactness and briefness

 

Model Description

 

FUD-Type-Input-Power Supply-Output

Type

3I: Three Phase AC Current Transducer

3U: Three Phase AC Voltage Transducer

AC Input

A1: 0~1A, A2: 0~5A, A3: 0~10A.

V0: 0~70V, V1: 0~120V, V2: 0~250V,

V3: 0~300V, V4: 0~450V, V5: 0~500V.

Power Supply

P1: AC110V±10%, P2: AC220V±15%,

P3: AC110V~330V.

DC Output

O1: 0~5V, O2: 1~5V, O3: 0~20mA,

O4: 4~20mA, O5: RS485.

Example 1: FUD-3I-A2-P2-O4

FUD Series Three Phase AC Current Transducer

Input: AC 0~5A

Power Supply: AC220V±15%

Output: DC 4~20mA

Example 2: FUD-3U-V2-P2-O4

Details: FUD Series Three Phase AC Voltage Transducer

Input: AC 0~250V

Power Supply: AC220V±15%

Output: DC4~20mA

Please check the Type, Input range, Output range and Power supply at your order.

 

Technical Index

 

Standard

GB/T 13850-1998, IEC688:1992

Accuracy

0.2%, 0.5%

Consumption

≤5VA

Accutacy drift

Annual Variation < 0.2%

Insulation Voltage

AC 2kV/min.1mA (Between Input ~ Output / Power)

Insulation Resistance

≥20MΩ (DC500V)

Surge voltage

5KV (Peak Value), 1.2/50μs

Response Time

≤350ms

Input Range

AC 0~10A ,AC 0~500V(Optional), 50/60Hz

Absorbed Power

<0.5VA/450V, <0.2VA/100V, <0.1VA/5A

Overload

Current: 2 times continuous,30 times /1s .Voltage: 2 times continuous

Load Resistance

Current output: RL≤550Ω

Voltage output: RL≥2kΩ

Working environment

Temperature: -10~50°C

RH: 20~90%, Without condensation

Storage conditions

Temperature: -40~70°C

RH: 20~95%, Without condensation

Installation

35mm DIN Sliding-way or M4 screws

Dimension

110mm×75mm×120mm

 

 

Company Information

 

 

Certifications

 

Packaging & Shipping

 

Our Services