Portable instrument for test and measurement of electrical GF303B 3 Phase Phantom Load

FOB Reference Price:Get Latest Price
US $0-10,000 / Set | 1 Set/Sets (Min. Order)
Supply Ability:
50 Set/Sets per Month
Port:
beijing shanghai shenzhen
Report Suspicious Activity
Overview
Quick Details
Place of Origin:
Beijing, China (Mainland)
Brand Name:
GFUVE
Model Number:
GF303B
Usage:
Auto Testing Machine
GF303B:
3 Phase Phantom Load
accuracy:
0.1
voltage:
0-120
current:
0-6
frequency:
45-65
harmonic:
2-63
size:
300*400*120mm
communication interface:
RS232
weight:
6.8kg
stability:
0.01/imin
Packaging & Delivery
Packaging Details
standard package
Delivery Time
15days

Specifications

1.weight home the most light weight 6.8kg
2.the fastest output:by high performance 32 bit cpu the frequency of 1.2G

 

3 Phase Phantom Load

 

 


Application

3 Phase Phantom Load is suitable for all the power supply company, electric power company distribution network automation departments, is also suitable for petrochemical, coal mine, railway and steel industry etc, to power automation departments use.

Functions and Features

1. Weight home the most light: the integrated module, weight of 6.8 kg;

2. The fastest output (10 ms) : by high performance 32 bit CPU, the frequency of 1.2 G;

3 Stable fastest (1 s) : hardware PID, the output of the standard resource without delay, fast response;

4. With the strongest load, load regulation rate fast, single phase with resistance sex load 15 VA; with pure capacitive load (0.33 uf);

5. Harmonic supreme: standard device can output 2-63 times higher harmonic;

6. Stability, and the best, stability for 0.01% / min; English or Chinese display.

7. Two kinds of frequency output: but at the same time points in different frequency voltage output; And amplitude can adjust arbitrarily output;

8. Software powerful, the operation is simple, convenient, quick, three steps can complete verification;

9. Debugging far move communication protocols of the most, as many as 20 kinds, covering domestic all factories statute;

10. The fastest verification;

Technical Data of  portable  power source

AC voltage output

Range: 0 ~ 140 V; Range to switch; (L1, L2, L3 phase)

Accuracy: 0.05% RG;

Adjusting range: (0-120) % RG;

Adjust fineness: 0.01% RG;

Stability: 0.01% / 1 min;

Distortion degree: < 0.1% (not capacitive load);

Output load: the rated each phase 15 VA;

Load regulation rate: < 0.02% RG.

AC current output

Range: 0 ~ 6A; Range to switch; (I1, I2, I3 phase)

Accuracy: 0.05% RG;

Adjusting range: (0-120) % RG;

Adjust fineness: 0.01% RG;

Stability: 0.01% / 1 min ;

Distortion degree: < 0.1% (not capacitive load);

Output load: the rated each phase 15 VA;

Load regulation rate: < 0.02% RG.

Power output

Accuracy: 0.05% RG;

Stability: 0.01% / 1 min.

Phase angle

Adjusting range: 0 ° ~ 359.999 °;

Resolution: 0.001 °;

Accuracy: 0.05 °.

Power factor

Adjusting range:-1 ~ 0 ~ + 1;

Resolution: 0.0001;

Accuracy: 0.0002.

Frequency

Adjusting range: 45 Hz ~ 65 Hz;

Resolution: 0.001 Hz;

Accuracy: 0.002 Hz.

Voltage current harmonic Settings

Harmonic times: 2 ~ 63;

Harmonic content: 0 ~ 40%;

Harmonic phase: 0 ° ~ 359.99 °;

Set accuracy: (0.1%) harmonic RG (relative to the base wave ratings)

Communication interface

RS232;

Volume and weight

Size: 300mm×400mm×120mm;

Weight: 6.8 kg;

Work power

Single phase AC 220 V± 10% /  frequency 50/60Hz.